THE ISSUE IDENTIFIED BY THESE REPORTS WAS CORRECTED IN THE LATEST UPDATE. WE ARE NO LONGER COLLECTING REPORTS.

Data Collection for P25 Stopping Reports

If you are experiencing the condition of P25 stopping decoding at random intervals where you must cycle power to restore decode, please fill out the table, below. You must be logged into this site in order to fill in the below. If you do not have a site login, go to TWikiRegistration and create one.

Note that the table will not look very pretty in edit mode (well, it might, depending on your screen resolution). To fill out an entry, please click EDIT below the table ( not at the top of the page). Please SAVE AND EXIT the table when you have completed your entry (the page is locked to other edits while the table is open).

If you have a general comment or more details than the report requests, enter them in the COMMENT area below the table. Note that you must save your table entry before saving a comment (if you don't your table entry will not be saved).

Reported By Report Date Model C-Ch Output C-Ch Output Port Hold Time Delay Time Priority Scan Trunked Priority Analog AGC Digital AGC P25 LP Filter WX Priority Close Call Any Channel Alert? Currently Active System Type(s) GPS-Controlled Location Alerts Enabled
LarryKoch 24 Sep 2009 23:17 BCD396XT Off None 0 0 Off On Off On Off Off Off No P25 Standard , Conventional No No
RichardVictor 24 Sep 2009 23:51 BCD396XT Off None 0 5 Off Off On On Off Off Off No P25 Standard No No
KarlSimonson 25 Sep 2009 10:10 BCD396XT On None 0 3 On Off On On On Off Off Yes P25 Standard , Conventional No No
JeffRehm 25 Sep 2009 21:42 BCD396XT Off None 2 5 Off Off Off Off Off Off Off No P25 Standard , EDACS Wide-Narrow , LTR , Conventional No No
StuartRoss 22 Nov 2009 10:45 BCD396XT Off None 0 0 Off Off Off Off Off Off Off No P25 Standard , Conventional No No
MarkMiller 23 Nov 2009 20:23 BCD396XT Off None 0 0 Off Off Off Off Off Off Off No P25 Standard No No
CLICK THIS EDIT BUTTON

Enter any necessary comments in the box below. Be sure to save your table entry before commenting.

Scanner completely locked up. Had to remove power to regain control.

-- RichardVictor - 25 Sep 2009

Scanner stops on P25 conventional channel that it doesn't decode well even with the correct NAC, locks up, no control response from keypad or scroll knob. Must have all power removed to restore. Is not always stopped on the same channel. Occurs at random. Scanner is connected to an outdoor antenna and AC power.

-- KarlSimonson - 25 Sep 2009

Scanner was scanning the P25 system I had programmed (visually on screen) however no audio came through the speaker. The signal bar was at 4-5 bars. At the time of problem the P25 system in question was the only thing I was scanning at that time. The problem happend after the scanner was on for a few hours. After troubleshooting as best I could, turned the scanner off for about 5-10 seconds. Turned back on and the P25 system scanned properly.

-- JeffRehm - 26 Sep 2009

-- JeffRehm - 26 Sep 2009

Addition...The keypad was still operating, unlike the other comments listed.

-- JeffRehm - 26 Sep 2009

-- StuartRoss - 22 Nov 2009

Scanner is normally just sitting on my desk. It is not in any direct sunlight. I keep the AC power adapter plugged in 24/7 ( batteries installed ) and scanner turned on 24/7. Scanner will just stop receiving transmissions. At that time, the scanner will not connect to the home computer using the USB cable. All key's still work, I can go in an edit settings, ect. Everything is acting normal, display show's it is scanning ( ID search ), you can see the GRP numbers flashing as it scan's.

To receive transmissions again, I had to unplug the AC power and take out the batteries. After re-install of both, it was working 100% again, including the USB to computer.

-- StuartRoss - 22 Nov 2009

Scanner stopped decoding after 7-10 days of constant A/C operation. 5 bars flash on/off. Reset scanner with power removal/reconnect. Currently working, but waiting for the freeze...

-- MarkMiller - 24 Nov 2009