SDS200 Firmware Update Change Log

All firmware updates are done using Sentinel.

1.10.00 Main (4/15/2019)

This firmware applies the following enhancements and bug fixes:
  • Fixed the issue of false TGID displaying during site hold.
  • Modified the valid condition of EDACS system ID.
  • Improved DMR OFT reception.
  • Improved NXDN48 (OFT) reception.
  • Slightly improved the clarity of analog and digital voice

1.09.02 Main (4/5/2019)

This firmware applies the following enhancements and bug fixes:
  • Fixed the issue of stopping scan during priority scan.
  • Fixed the issue the open squelch backlight does not turn off till hold time expires
  • Changed housekeeping off while scanning one site and detecting its control channel (drop in reception every 2 seconds).

1.02.01 Sub / 1.08.05 Main (3/7/2019)

Be sure to also update Sentinel when applying this update.

This firmware update applies the following new settings and bug fixes:

  • Added an "AMP OFF Timer" setting that determines how long the amplifier stays on after a transmission ends. If you hear hum between transmissions, change this from Infinite to one of the available settings.
  • Added "Wide Normal", "Wide Invert" and "Wide Auto" filter options for FM performance improvement. When you pick this setting, the filter becomes weaker for interference on a nearby frequency. However, the linearity of the IF can be maintained even when there is strong interference within the band, and the reception may be improved in some cases.
  • Added an option to display the filter setting when customizing the display.
  • Improved a reception dropout issue where dropouts are often accompanied by "LINK" icon appearing at start of dropout.
  • Improved crackling noise on analog.
  • Improved the reports that some REC files created have no audio captured at replay.
  • Added a prompt to exit certain modes.

1.02.00 Sub / 1.07.04 Main

First release firmware adds additional countermeasures to help in strong signal areas (especially for VHF/UHF). It also adds a user option to set the default RF High Pass Filter (HPF) used.

MENU --> SETTINGS --> GLOBAL AUTO FILTER

  • Normal (always use HPF)
  • Invert (always use inverted HPF)
  • Auto (try HPF then if no signal detected to open squelch, try inverted HPF)
Note: If Auto is selected, conventional scan and search speed will be greatly slowed, as every frequency on which a signal is not detected on first pass will be rescanned using the inverted HPF setting.

MENU --> MANAGE FAVORITES --> REVIEW/EDIT SYSTEM --> EDIT SITE --> SET FILTER (Setting menu for trunked systems)

  • Global (use the setting from GLOBAL AUTO FILTER)
  • Normal
  • Invert
  • Auto

MENU --> MANAGE FAVORITES --> REVIEW/EDIT SYSTEM --> EDIT DEPARTMENT --> SET FILTER (Setting menu for conventional systems)

  • Global (use the setting from GLOBAL AUTO FILTER)
  • Normal
  • Invert
  • Auto

MENU --> SRCH/CLOCALL OPT --> SET FILTER (Setting menu for Close Call and Search)

  • Global (use the setting from GLOBAL AUTO FILTER)
  • Normal
  • Invert
  • Auto
Topic attachments
I Attachment Action SizeSorted ascending Date Who Comment
PDFpdf RTSP.pdf manage 36.8 K 23 Jan 2019 - 21:00 UnknownUser  
PDFpdf SDS200_Virtual_Serial_on_Network_Specification_V1_00.pdf manage 73.6 K 23 Jan 2019 - 21:00 UnknownUser  
PDFpdf SDS200_RemoteCommand_Specification_V0_01.pdf manage 211.9 K 23 Jan 2019 - 21:00 UnknownUser  
PDFpdf SDSx00_File_Specification_V1_03.pdf manage 329.3 K 23 Jan 2019 - 21:00 UnknownUser  
PDFpdf SDS200_FontData_V1_00.pdf manage 1341.6 K 23 Jan 2019 - 21:00 UnknownUser  
Topic revision: r9 - 01 May 2019 - PaulOpitz

 
This site is powered by the TWiki collaboration platformCopyright © 2008-2021 by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding TWiki? Send feedback